Off-Grid Solar Calculators

Inverters and charge controllers

PWM vs MPPT Efficiency & Yield Comparison

A PWM controller roughly clamps the array to battery voltage, so you harvest about V_battery / Vmp of the panel’s rated power. An MPPT converter keeps the array near Vmp and typically delivers around 95% of that power to the battery.

Inputs

W

System voltage of the battery or series string.

V

Must stay above battery voltage for the PWM model to apply.

h

Results

Those inputs are outside what this tool can recommend. Check the notes — a fuse above cable or module rating is a fail, not a size to install. Other tools need values greater than zero and within the stated limits.

PWM daily harvest
MPPT daily harvest
Extra Wh from MPPT

Recommended gear

Engineering methodology

A PWM controller roughly holds the array near battery voltage, so harvest ≈ P_array × (V_battery / Vmp) × peak sun hours. An MPPT converter keeps the array near Vmp: harvest ≈ P_array × MPPT efficiency × peak sun hours. The model requires Vmp greater than battery voltage. It is a yield comparison, not a laboratory efficiency test.

Frequently asked questions

When is a cheap PWM controller good enough?

When module Vmp is already close to battery voltage (classic “12 V” panels on a 12 V bank). As Vmp rises well above V_battery, PWM leaves more energy unharvested and MPPT usually wins.

Why must array Vmp stay above battery voltage in this comparison?

The PWM ratio V_battery / Vmp is only meaningful if the array can still push current into the battery. If Vmp is below battery voltage, a PWM controller cannot charge usefully and the model is marked invalid.

Is MPPT always about 30% better than PWM?

No. The gap is Vmp versus battery voltage, temperature and sun hours. Matched 12 V modules on 12 V PWM can be close. High-voltage grid modules on a 12 V PWM controller waste a large fraction of nameplate power.