Off-Grid Solar Calculators
Solar Tilt Angle & Azimuth Estimator
https://www.offgridsizing.com/calculators/solar-tilt-azimuth/
Engineering estimate only — not a system design. Verify with a licensed electrician.
Solar Tilt Angle & Azimuth Estimator
A fixed array is rarely best at a tilt equal to latitude. A slightly shallower annual tilt usually beats a latitude-equals-tilt rule once you are past about 25°. Face true south in the northern hemisphere and true north in the southern hemisphere.
Off-grid system flow
Follow the DC path. Nodes open the matching sizer; arrows open the wire-gauge tool for that run.
Inputs
Results
Please tick the box above to display the Result.
Engineering methodology
Annual fixed tilt is piecewise: 0.87 × |latitude| below about 25°, then Landau’s mid-latitude fit 0.76 × |latitude| + 3.1° at and above 25° (both clamped 0–90°). Landau published that fit for 25–50°; it is carried above 50° as well, because a latitude-equals-tilt branch jumps about 9° at the boundary and over-tilts northern Europe. Summer tilt ≈ |latitude| − 15°. Winter tilt ≈ |latitude| + 15°. Azimuth is 180° (true south) in the northern hemisphere and 0° (true north) in the southern hemisphere. Magnetic declination is not applied. This is a rule of thumb, not a sun-path or PVGIS yield study.
Related calculations
- array size in peak sun hours — tilt does not replace a winter PSH figure
- hot-roof power loss — steeper tilt can change cell temperature slightly, but γ still applies
Frequently asked questions
Should solar panels face magnetic south or true south?
True south (azimuth 180°) in the northern hemisphere. A compass points to magnetic south/north; declination can be many degrees. This tool reports true azimuth only.
Is latitude-equals-tilt the best annual angle?
Not always. Above about 25° latitude, a slightly shallower annual tilt (Landau: 0.76×lat + 3.1°) usually beats a strict latitude tilt for year-round energy — near 52° that is roughly 43° rather than 52°. Roof pitch and snow shedding can override the number.
Why add 15° in winter and subtract 15° in summer?
The sun is lower in winter and higher in summer. The ±15° rule of thumb tracks that elevation. It is not a sun-path simulation and ignores shading and albedo.
More in this cluster
All tools in this clusterSolar panels
Off-Grid Cabin Daily Solar Need
Add up fridge, lights, laptop, water pump and other cabin loads to get a daily watt-hour budget for solar sizing.
Solar panels
Series vs Parallel Solar Calculator
Add Voc in series and Isc in parallel to check string voltage, array current and nameplate watts against your MPPT limits.
Solar panels
Solar Array Sizer
Estimate how many solar panels you need from daily watt-hours, panel watts and peak sun hours, including a realistic derate.
Solar panels
Solar Panel Temperature Loss Calculator
Estimate how many watts a solar panel loses when cell temperature rises above 25 °C using the Pmax temperature coefficient.
Solar panels
Solar Roof Space & Weight Calculator
Estimate square meters of roof and kilograms of dead load for a given number of solar panels.